2003-08-28 11:38:24, RS485(1), >RTM1138234482808200313106100000;*61<, string, GPS
2003-08-28 11:38:23, CLOCK, 2003-08-28 11:38:23, UTC, GPS Time
2003-08-28 11:38:40, CLOCK, 2003-08-27 19:48:31, UTC, Most recent CPU boot
2003-08-28 11:42:02, RS485(6), ADCP
2003/08/28 11:49:06.71 00002
Hdg: 259.3 Pitch: -24.2 Roll: 21.6
Temp: 27.5 SoS: 1540 BIT: 00
Bin    Dir    Mag     E/W     N/S    Vert     Err   Echo1  Echo2  Echo3  Echo4
  1    --      --     279    -207    -235  -32768     44     49     46     46
  2    --      --     436    -213    -344  -32768     41     44     44     46
  3    --      --     550    -567    -267  -32768     42     43     43     45
  4    --      --  -32768  -32768  -32768  -32768     44     43     44     44
  5    --      --  -32768  -32768  -32768  -32768     42     43     42     45
  6    --      --  -32768  -32768  -32768  -32768     43     45     45     46
  7    --      --  -32768  -32768  -32768  -32768     45     45     43     46
  8    --      --     618    -271    -238  -32768     43     44     44     44
  9    --      --  -32768  -32768  -32768  -32768     42     44     45     44
 10    --      --  -32768  -32768  -32768  -32768     43     44     40     46
 11    --      --     438     214    -493  -32768     43     44     43     45
 12    --      --     337    -530    -159  -32768     42     44     42     46
 13    --      --  -32768  -32768  -32768  -32768     42     44     41     45
 14    --      --  -32768  -32768  -32768  -32768     42     44     44     45
 15    --      --     457     468    -505  -32768     44     44     45     46
 16    --      --  -32768  -32768  -32768  -32768     43     45     44     46
 17    --      --  -32768  -32768  -32768  -32768     45     44     43     47
 18    --      --  -32768  -32768  -32768  -32768     44     45     42     46
 19    --      --  -32768  -32768  -32768  -32768     42     44     44     45
 20    --      --  -32768  -32768  -32768  -32768     43     44     43     44
 21    --      --  -32768  -32768  -32768  -32768     43     44     43     45
 22    --      --  -32768  -32768  -32768  -32768     43     45     44     46
 23    --      --     533     415    -474  -32768     41     44     44     46
 24    --      --  -32768  -32768  -32768  -32768     44     45     44     45
 25    --      --     264    -122    -335  -32768     43     43     42     46
 26    --      --  -32768  -32768  -32768  -32768     43     44     43     44
 27    --      --     430     318    -440  -32768     43     44     44     45
 28    --      --  -32768  -32768  -32768  -32768     42     44     43     44
 29    --      --  -32768  -32768  -32768  -32768     41     44     44     45
 30    --      --  -32768  -32768  -32768  -32768     43     44     42     46
 31    --      --  -32768  -32768  -32768  -32768     43     44     44     44
 32    --      --  -32768  -32768  -32768  -32768     44     43     43     44
 33    --      --  -32768  -32768  -32768  -32768     43     44     42     46
 34    --      --  -32768  -32768  -32768  -32768     44     44     43     45
 35    --      --  -32768  -32768  -32768  -32768     43     44     44     45
 36    --      --  -32768  -32768  -32768  -32768     44     45     43     46
 37    --      --  -32768  -32768  -32768  -32768     44     44     42     46
 38    --      --  -32768  -32768  -32768  -32768     44     45     43     45
 39    --      --  -32768  -32768  -32768  -32768     43     43     43     45
 40    --      --  -32768  -32768  -32768  -32768     44     44     45     45


2003-08-28 11:43:55, RS485(2),  *
 *0000000
, count, Rain Gauge
2003-08-28 11:44:51, RS485(3), TS
 29.0422, 0.00004,   -0.095,   0.0133
S>, , CTD (Upper)
2003-08-28 11:47:34, RS485(4), RS485 TIME-OUT ERROR, , CTD 4 (Lower)
2003-08-28 11:47:47, RS485(5), PS=+014.474
, PSI, Barometer (Heise DXD)
2003-08-28 11:47:56, AD(0), 5.54443359375, volts, Temp
2003-08-28 11:47:56, AD(1), 8.5888671875, volts, Hum
2003-08-28 11:47:56, AD(2), 0.625, volts, PSP
2003-08-28 11:47:56, AD(3), 0.93505859375, volts, PIR/Dome Temp
2003-08-28 11:47:56, AD(4), 0.95947265625, volts, PIR/Case Temp
2003-08-28 11:47:56, AD(5), -1.201171875, volts, PIR/Thermopile
2003-08-28 11:48:04, CLOCK, 558, seconds, Time to read all sensors
2003-08-28 11:57:41, RS485(6), ADCP
2003/08/28 12:04:44.89 00002
Hdg: 259.2 Pitch: -24.2 Roll: 21.6
Temp: 27.5 SoS: 1540 BIT: 00
Bin    Dir    Mag     E/W     N/S    Vert     Err   Echo1  Echo2  Echo3  Echo4
  1    --      --     948    -294     380  -32768     44     50     43     44
  2    --      --  -32768  -32768  -32768  -32768     44     45     42     44
  3    --      --  -32768  -32768  -32768  -32768     43     44     43     45
  4    --      --  -32768  -32768  -32768  -32768     43     44     43     45
  5    --      --  -32768  -32768  -32768  -32768     43     45     43     44
  6    --      --     651    1408    -372  -32768     42     44     43     45
  7    --      --  -32768  -32768  -32768  -32768     45     43     42     47
  8    --      --  -32768  -32768  -32768  -32768     43     44     44     45
  9    --      --     900     100     336  -32768     44     46     41     46
 10    --      --  -32768  -32768  -32768  -32768     42     44     43     45
 11    --      --  -32768  -32768  -32768  -32768     43     43     43     44
 12    --      --     765    1045    -338  -32768     43     44     45     45
 13    --      --  -32768  -32768  -32768  -32768     43     44     44     46
 14    --      --  -32768  -32768  -32768  -32768     42     44     44     45
 15    --      --  -32768  -32768  -32768  -32768     42     45     42     46
 16    --      --  -32768  -32768  -32768  -32768     44     45     45     46
 17    --      --  -32768  -32768  -32768  -32768     43     43     44     45
 18    --      --  -32768  -32768  -32768  -32768     43     44     43     46
 19    --      --  -32768  -32768  -32768  -32768     43     44     43     45
 20    --      --  -32768  -32768  -32768  -32768     43     43     44     46
 21    --      --  -32768  -32768  -32768  -32768     44     43     43     46
 22    --      --     949      54     377  -32768     43     44     41     46
 23    --      --    1027     203     311  -32768     43     45     43     46
 24    --      --     923     374      70  -32768     43     45     43     47
 25    --      --     726     890     -68  -32768     42     44     42     44
 26    --      --  -32768  -32768  -32768  -32768     42     44     43     45
 27    --      --  -32768  -32768  -32768  -32768     42     44     43     45
 28    --      --     804     689      90  -32768     44     45     42     45
 29    --      --     998     569     148  -32768     42     43     44     46
 30    --      --  -32768  -32768  -32768  -32768     43     44     41     46
 31    --      --  -32768  -32768  -32768  -32768     43     43     44     46
 32    --      --  -32768  -32768  -32768  -32768     43     44     44     46
 33    --      --  -32768  -32768  -32768  -32768     43     44     43     45
 34    --      --  -32768  -32768  -32768  -32768     44     44     44     45
 35    --      --  -32768  -32768  -32768  -32768     42     44     42     47
 36    --      --  -32768  -32768  -32768  -32768     42     44     43     45
 37    --      --  -32768  -32768  -32768  -32768     43     44     44     45
 38    --      --  -32768  -32768  -32768  -32768     43     43     42     45
 39    --      --  -32768  -32768  -32768  -32768     43     44     43     46
 40    --      --  -32768  -32768  -32768  -32768     42     44     43     45


2003-08-28 11:59:26, RS485(2),  *
 *0000000
, count, Rain Gauge
2003-08-28 12:00:18, RS485(3), TS
 29.5943, 0.00005,   -0.096,   0.0134
S>, , CTD (Upper)
2003-08-28 12:02:55, RS485(4), RS485 TIME-OUT ERROR, , CTD 4 (Lower)
2003-08-28 12:03:06, RS485(5), PS=+014.475
, PSI, Barometer (Heise DXD)
2003-08-28 12:03:13, AD(0), 5.5859375, volts, Temp
2003-08-28 12:03:14, AD(1), 8.37158203125, volts, Hum
2003-08-28 12:03:14, AD(2), 0.8837890625, volts, PSP
2003-08-28 12:03:14, AD(3), 0.8935546875, volts, PIR/Dome Temp
2003-08-28 12:03:14, AD(4), 0.927734375, volts, PIR/Case Temp
2003-08-28 12:03:14, AD(5), -1.2353515625, volts, PIR/Thermopile
2003-08-28 12:03:20, CLOCK, 539, seconds, Time to read all sensors